Vertical concealed fan coil unit
Product features
reasonable design
The structure of the fan coil unit is exquisite, compact, sturdy and durable, with a beautiful and noble appearance. The fan Zhulai coil adopts a galvanized sheet shell, and the condensate tray is formed by open molding technology. The insulation material that meets fire protection standards and has no welds is connected to the water tray as a whole.
Easy to install
Fan coil unit has a small volume: the body design is lightweight. The drainage pipes and wiring are easy to install, and the left and right connection and return air methods can be changed at any time to match the on-site situation. The unit can be installed in any space.
Low noise
The motor adopts permanent magnet synchronous motor, which is efficient, energy-saving, higher efficiency, and lower noise; Reasonable fan and airflow structure design, high-quality sound-absorbing and insulation materials, make the unit noise lower than the national standard 1-3dB (A).
High heat exchange efficiency
High efficiency of fan coil units: Advanced tube expansion technology ensures close contact between copper tubes and aluminum foil in the heat exchanger, resulting in good heat transfer performance.
Place of use
Widely used in various places such as hotels, theaters, shopping malls, office buildings, schools, warehouses, etc; As an industrial air conditioner, it can also meet the needs of various industries such as electronics, chemical, medical, pharmaceutical, cigarette, food, and light industry.
Vertical concealed fan coil unit with upper air outlet (two pipes and three rows of pipes) A-direction view
Outline dimension table for upper air outlet (two pipes and three rows) of vertical concealed fan coil unit
Vertical concealed fan coil unit side air outlet (two pipes and three rows of pipes) A-direction view
Vertical concealed fan coil unit side air outlet (two pipes and three rows of pipes) external dimension table
Vertical concealed fan coil unit (3-row pipe, AC motor)
Note:
1. Cooling: inlet and outlet water temperature of 7 ℃/12 ℃, inlet air dry bulb temperature DB27.0 ℃, wet bulb temperature WB19.5 ℃.
2. Heating: inlet and outlet water temperature 60 ° C/50 ℃, inlet air dry bulb temperature DB21.0C.
3. The noise in the table is measured by the unit in a fully anechoic room with a background noise of 16.5dB (A) (according to GB/T19232-2019).
4. The static pressure at the outlet of the low static pressure compressor group with air outlet and filter is 0Pa; When there is no air outlet and filter, the static pressure at the outlet is 12Pa.
5. The power consumed by the motor load is the input power (also known as reference condition consumption), and the power indicated on the motor nameplate is the nominal power, which is the output power of the motor when operating under rated conditions.
6. If the actual operating conditions are different from the standard operating conditions, please refer to the correction coefficient table data in the sample for correction.
Correction method: Actual cooling (heat) capacity=rated cooling (heat) capacity X working condition correction factor.
7. Our company reserves the right to make product improvements or design changes without prior notice, and all products are based on the actual product.